SLAAEI4 August 2024 TAC5111-Q1 , TAC5212-Q1 , TAC5311-Q1 , TAC5312-Q1 , TAC5411-Q1 , TAC5412-Q1 , TAD5212-Q1
Table 4-1 shows the parameters of the Brown-out protection algorithm. The parameters reside in the 32-bit-wide coefficient memory (Book 0, page 26) of the device.
Brown-Out Parameter | Function and Description |
---|---|
Critical Level (V) | A user-defined VBAT level parameter to initiate a gain increase or decrease to the output signal |
Gain Level (dB) | The amount of gain applied to the output signal level when a critical VBAT level is triggered |
Attack Rate (dB/step) | The step rate response when the BOP triggers a gain decrease |
Release Rate (dB/step) | The step rate response when the BOP triggers a gain increase |
Hold Counter (ms) | The amount of time taken following a change in VBAT before the brown-out protector attenuates the output signal level |