SLAS564I August 2007 – December 2024 CDCE937 , CDCEL937
PRODUCTION DATA
At a given input frequency (ƒIN), the output frequency (ƒOUT) of the CDCEx913 are calculated with Equation 1.
where
The target VCO frequency (ƒVCO) of each PLL is calculated with Equation 2.
The PLL internally operates as fractional divider and needs the following multiplier/divider settings:
where
N′ = N × 2P
N ≥ M;
80MHz ≤ ƒVCO ≤ 230MHz
16 ≤ Q ≤ 63
0 ≤ P ≤ 4
0 ≤ R ≤ 51
Example: | |||
for ƒIN = 27MHz; M = 1; N = 4; Pdiv = 2 | for ƒIN = 27MHz; M = 2; N = 11; Pdiv = 2 | ||
→ | fOUT = 54MHz | → | fOUT = 74.25MHz |
→ | fVCO = 108MHz | → | fVCO = 148.50MHz |
→ | P = 4 – int(log24) = 4 – 2 = 2 | → | P = 4 – int(log25.5) = 4 – 2 = 2 |
→ | N' = 4 × 22 = 16 | → | N' = 11 × 22 = 44 |
→ | Q = int(16) = 16 | → | Q = int(22) = 22 |
→ | R = 16 – 16 = 0 | → | R = 44 – 44 = 0 |
The values for P, Q, R, and N’ are automatically calculated when using TI Pro-Clock™ software.