SLAU320AJ July 2010 – May 2021
The same method is used to program the fuse for the TEST pin MSP430 devices, with the exception that the fuse-blow voltage, VPP, is now applied to the TEST input pin.
IR_SHIFT("IR_PREPARE_BLOW") | |
MsDelay(1) : Delay for 1ms | |
Connect VPP to TEST pin | |
Wait until VPP input has settled (depends on VPP source) | |
IR_SHIFT("IR_EX_BLOW") | |
MsDelay(1) : Delay for 1ms | |
Remove VPP from TEST pin | |
Reset the JTAG state machine (ResetTAP) |