SLAU723A October 2017 – October 2018 MSP432E401Y , MSP432E411Y
Up to four tamper events are stored in HIB Tamper Log n (HIBTPLOGn) registers within the Hibernate module. When a tamper event occurs the following status is logged:
NOTE
24-hour mode must be used if RTC calendar mode is enabled. This mode is selected by setting the CAL24 bit in HIB Calendar Control (HIBCALCTL) register.
On the assertion of a qualified tamper event (rising edge) on any of the TMPRn pins or an XOSC failure signal, the current status of all tamper inputs are logged in the HIBTPLOGn register.