SLAZ092AB October 2012 – May 2021 CC430F5133
RF1A Module
Functional
LVERR flag set when radio in SLEEP or IDLE and VCORE = 0, 1
The low-voltage error flag (LVERR) is set when the radio is in the SLEEP or IDLE state and VCORE = 0 or 1, which is contrary to the behavior specified in the CC430 User's Guide.
None.