SLAZ153I October 2012 – May 2021 MSP430F2003
SDA Module
Functional
Internal reference generator performance is beyond the specification limits
The SD16_A reference generator may not meet the maximum temperature coefficient specification of 50 ppm/degC.
The SD16_A internal reference can be adjusted to operate within the specification by writing 0x61 to memory location 0xBF. This corrects the temperature coefficient of the internal reference and centers the typical voltage to 1.20 V.