SLAZ205H October 2012 – May 2021 MSP430F4351
USART Module
Functional
Unpredictable program execution
USART interrupts requested by URXS can result in unpredictable program execution if this request is not served within two bit times of the received data.
Ensure that the interrupt service routine is entered within two bit times of the received data.