SLAZ215H October 2012 – May 2021 MSP430F449
USART Module
Functional
Start edge of received characters may be ignored
When using the USART in UART mode with UxBR0 = 0x03 and UxBR1 = 0x00, the start edge of received characters may be ignored due to internal timing conflicts within the UART state machine. This condition does not apply when UxBR0 is > 0x03.
None