SLFS078C October 2006 – April 2024 TLC555-Q1
PRODUCTION DATA
PARAMETER | TEST CONDITIONS | MIN | TYP | MAX | UNIT | |
---|---|---|---|---|---|---|
Supply voltage sensitivity of timing interval | VDD = 5 V to 15 V, CT = 0.1 μF RA = RB = 1 kΩ to 100 kΩ (1) |
0.1 | 0.5 | %/V | ||
tr | Output pulse rise time | RL = 10 MΩ, CL = 10 pF | 20 | 75 | ns | |
tf | Output pulse fall time | RL = 10 MΩ, CL = 10 pF | 15 | 60 | ns | |
fmax | Maximum frequency in astable mode | RA = 470 Ω, CT = 200 pF RB = 200 Ω (1) | 1.2 | 2.1 | MHz |