Table 6-1 lists the device functional modes. For a valid reset voltage condition, use an external pullup resistor to VDD (if using the RESET functionality), or short the RESET pin directly to VDD (if the RESET functionality is not used).
RESET | TRIGGER VOLTAGE(1) | THRESHOLD VOLTAGE(1) | OUTPUT | DISCHARGE SWITCH |
---|---|---|---|---|
Low | Irrelevant | Irrelevant | Low | On |
High | < 1/3 VDD | Irrelevant | High | Off |
High | > 1/3 VDD | > 2/3 VDD | Low | On |
High | > 1/3 VDD | < 2/3 VDD | As previously established |