SLLS792B June 2007 – July 2021 TRS3221E
PRODUCTION DATA
INPUTS(1) | OUTPUT | DRIVER STATUS | |||
---|---|---|---|---|---|
DIN | FORCEON | FORCEOFF | VALID RIN RS-232 LEVEL | DOUT | |
X | X | L | X | Z | Powered off |
L | H | H | X | H | Normal operation with automatic power down disabled |
H | H | H | X | L | |
L | L | H | Yes | H | Normal operation with automatic power down enabled |
H | L | H | Yes | L | |
L | L | H | No | Z | Powered off by automatic power-down feature |
H | L | H | No | Z |
INPUTS(1) | OUTPUT | RECEIVER STATUS | ||
---|---|---|---|---|
RIN | EN | VALID RIN RS-232 LEVEL | ROUT | |
X | H | X | Z | Output off |
L | L | X | H | Normal operation |
H | L | X | L | |
Open | L | No | H |
INPUTS(1) | OUTPUT | |||
---|---|---|---|---|
RIN | FORCEON | FORCEOFF | EN | INVALID |
L | X | X | X | H |
H | X | X | X | H |
Open | X | X | X | L |