4 Revision History
Changes from Revision F (April 2023) to Revision G (May 2024)
- Updated numbering format for tables, figures and cross-references
throughout document.Go
- Updated Thermal Characteristics, Safety Limiting Values, and Thermal
Derating Curves to provide more accurate system-level thermal
calculations.Go
- Updated electrical and switching characteristics to match device
performance.Go
Changes from Revision E (March 2020) to Revision F (April 2023)
- Changed standard name from: "DIN VDE V 0884-11:2017-01" to: "DIN EN
IEC 60747-17 (VDE 0884-17)" throughout the documentGo
- Removed standard revision and year references from all standard
names throughout the documentGo
- Changed test conditions and values of Maximum surge isolation voltage (VIOSM) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Added Maximum impulse voltage (VIMP) specification per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Clarified method b test conditions of Apparent charge (qPD)Go
- Removed references to standard IEC/EN/CSA 60950-1 throughout the documentGo
- Changed working voltage lifetime margin from 87.5% to 50%, minimum
required insulation lifetime from 37.5 years to 30 years, and insulation
lifetime per TDDB from 135 years to 169 years in
Insulation Lifetime
per DIN EN IEC 60747-17 (VDE 0884-17)Go
- Changed Figure 9-6 per DIN EN IEC 60747-17 (VDE 0884-17)Go
Changes from Revision D (January 2019) to Revision E (March 2020)
- Added ISO7721B device to this data sheet for applications that require basic insulation only. Previous data sheet literature number for ISO7721B was SLLSEY9AGo
- Changed VDE standard name From: DIN V VDE V 0884-11:2017-01 To: DIN VDE V 0884-11:2017-01 throughout the document Go
- Changed UL certification bullet in Section 1 From: '5000 VRMS (DW-16, DWV-8) and 3000 VRMS (D-8) Isolation Rating per UL 1577' To: 'UL 1577 component recognition program' Go
- Combined CSA, CQC, and TUV Section 1 bullets into a single bulletGo
- Updated certification informationGo
Changes from Revision C (July 2018) to Revision D (January 2019)
- Made editorial and cosmetic changes throughout the documentGo
- Changed From: "Isolation Barrier Life: >40 Years" To:">100-Year Projected Lifetime at 1.5 kVRMS Working Voltage" in Section 1
Go
- Added "Up to 5000 VRMS Isolation Rating" in Section 1
Go
- Added "Up to 12.8 kV Surge Capability" in Section 1
Go
- Added "±8 kV IEC 61000-4-2 Contact Discharge Protection across Isolation Barrier" in Section 1
Go
- Added "Automotive Version Available: ISO772x-Q1" in Section 1
Go
- Deleted "Certification Planned" statement throughout the document Go
- Updated Section 2 listGo
- Updated Figure 3-1 to show two isolation capacitors in series per channel instead of a single isolation capacitor Go
- Added "Contact discharge per IEC 61000-4-2" specification of 8000 VGo
- Changed "signaling rate" to "data rate" and added table noteGo
- Updated DWV-8 and DW-16 package's VIORM and VIOWM values, added TDDB figure reference, and updated test conditions for VIOTM, VIOSM, and qpd
Go
- Updated certification informationGo
- Added Section 9.2.3.1 sub-section under Section 9.2.3 sectionGo
- Added 'How to use isolation to improve ESD, EFT and Surge immunity in industrial systems' application report to Section 12.2 sectionGo
Changes from Revision B (March 2017) to Revision C (July 2018)
- Added the 8-pin SOIC package (DWV) to the data sheet Go
- Updated the VDE and CSA certification description throughout the documentGo
- Updated Climatic category for D packageGo
- Updated Maximum working voltages for DW-16 and D-8Go
- Switched the line colors for VCC at 2.5 V and VCC at 3.3 V in the Low-Level Output Voltage vs Low-Level Output Current graphGo
- Deleted EN from the Common-Mode Transient Immunity Test Circuit figureGo
- Added the Device Support sectionGo
Changes from Revision A (December 2016) to Revision B (March 2017)
- Added D-8 values for TUV columnGo
- Changed minimum CMTI value from 40 kV/μs to 85 kV/μs throughout the documentGo
- Added the Receiving Notification of Documentation Updates sectionGo
- Changed the Electrostatic Discharge Caution statement Go
Changes from Revision * (November 2016) to Revision A (December 2016)
- Changed Feature From: IEC 60950-1, IEC 60601-1 and IEC 61010-1 End Equipment Standards To: IEC 60950-1 and IEC 60601-1 End Equipment Standards Go
- Added Climatic category to tableGo
- Updated CSA column and changed DW package to (DW-16)Go
- Changed tie TYP value from 1.5 to 1 throughout the documentGo