12 Revision History
Changes from Revision G (June 2023) to Revision H (January 2024)
- Updated numbering format for tables, figures and cross-references
throughout documentGo
- Updated Thermal Characteristics, Safety Limiting Values, and Thermal
Derating Curves to provide more accurate system-level thermal
calculationsGo
- Updated electrical and switching characteristics to match device
performanceGo
Changes from Revision F (November 2022) to Revision G (June 2023)
- Changed standard name From: "DIN V VDE V 0884-11:2017-01" To: "DIN
EN IEC 60747-17 (VDE 0884-17)" throughout the documentGo
- Removed references to standard IEC/EN/CSA 60950-1 throughout the
documentGo
- Removed standard revision and year references from all standard
names throughout the documentGo
- Added Maximum impulse voltage (VIMP) per DIN EN IEC 60747-17 (VDE 0884-17) Go
- Changed test conditions and values of Maximum surge isolation voltage (VIOSM) specification per DIN EN IEC 60747-17 (VDE 0884-17) Go
- Clarified method b test conditions of Apparent charge (qPD) Go
- Changed maximum working voltage value From: 250 VRMS To: 400 VRMS for DBQ-16 devices per GB 4943.1Go
- Changed working voltage lifetime margin from: 87.5% to: 50%, minimum
required insulation lifetime from: 37.5 years to: 30 years and insulation
lifetime per TDDB from: 135 years to: 169 years per DIN EN IEC 60747-17 (VDE
0884-17)Go
- Changed Figure 8-7 per DIN EN IEC 60747-17 (VDE 0884-17)Go
Changes from Revision E (February 2019) to Revision F (November 2022)
- Updated the numbering format for tables, figures, and
cross-references throughout the documentGo
Changes from Revision D (November 2018) to Revision E (February 2019)
- Changed CPG parameter description from "External clearance" to "External creepage"Go
Changes from Revision C (January 2018) to Revision D (November 2018)
- Made editorial and cosmetic changes throughout the documentGo
- Changed From: "Isolation Barrier Life: >40 Years" To:">100-Year Projected Lifetime" in Section 1
Go
- Added "Up to 5000 VRMS Isolation Rating" in Section 1
Go
- Added "Up to 12.8 kV Surge Capability" in Section 1
Go
- Added "±8 kV IEC 61000-4-2 Contact Discharge Protection across Isolation Barrier" in Section 1
Go
- Added "Automotive Version Available: ISO776x-Q1" in Section 1
Go
- Deleted "Certification Planned" statement throughout the document Go
- Updated Section 2 listGo
- Changed Figure 3-1 to show series isolation capacitorsGo
- Added table note to Data rate specificationGo
- Changed VIORM value for DW-16 package from "1414 VPK" to "2121 VPK
Go
- Changed VIOWM values for DW-16 package from "1000 VRMS" and "1414 VDC" to "1500 VRMS" and "2121 VDC"Go
- Updated certification informationGo
- Changed From: "Table 2" To: "Safety Related Certifications" in Table 7-1 table noteGo
- Changed Figure 7-3
Go
- Added Section 8.2.3.1 sub-section under Section 8.2.3 sectionGo
Changes from Revision B (November 2017) to Revision C (January 2018)
- Changed the CIO value for the DBQ package from 1.1 to 0.9 pFGo
Changes from Revision A (August 2017) to Revision B (November 2017)
- Changed the CSA certification wording in the Features and Safety-Related Certifications tableGo
- Changed the isolation voltage for the DBQ-16 package from 2500 to 3000 VRMS
Go
- Added the maximum transient isolation voltage for the DW-16 package of the ISO7761, ISO7762, and ISO7763 devices and changed the maximum value for the DBQ-16 package from 3600 to 4242 for all devicesGo
- Changed table note and table condition of safety limiting valuesGo
- Added the supply current vs data rate graphs for the ISO7761, ISO7762, and ISO7763 in the Typical Characteristics sectionGo
Changes from Revision * (August 2017) to Revision A (August 2017)
- Deleted EN from the Common-Mode Transient Immunity Test Circuit figureGo
- Changed the VCC1 and VCC2 signals in the Typical ISO7761 Circuit Hook-up figureGo