SLLSER1H August   2017  – January 2024 ISO7760 , ISO7761 , ISO7762 , ISO7763

PRODUCTION DATA  

  1.   1
  2. Features
  3. Applications
  4. Description
  5. Pin Configuration and Functions
  6. Specifications
    1. 5.1  Absolute Maximum Ratings
    2. 5.2  ESD Ratings
    3. 5.3  Recommended Operating Conditions
    4. 5.4  Thermal Information
    5. 5.5  Power Ratings
    6. 5.6  Insulation Specifications
    7. 5.7  Safety-Related Certifications
    8. 5.8  Safety Limiting Values
    9. 5.9  Electrical Characteristics—5-V Supply
    10. 5.10 Supply Current Characteristics—5-V Supply
    11. 5.11 Electrical Characteristics—3.3-V Supply
    12. 5.12 Supply Current Characteristics—3.3-V Supply
    13. 5.13 Electrical Characteristics—2.5-V Supply 
    14. 5.14 Supply Current Characteristics—2.5-V Supply
    15. 5.15 Switching Characteristics—5-V Supply
    16. 5.16 Switching Characteristics—3.3-V Supply
    17. 5.17 Switching Characteristics—2.5-V Supply
    18. 5.18 Insulation Characteristics Curves
    19. 5.19 Typical Characteristics
  7. Parameter Measurement Information
  8. Detailed Description
    1. 7.1 Overview
    2. 7.2 Functional Block Diagram
    3. 7.3 Feature Description
      1. 7.3.1 Electromagnetic Compatibility (EMC) Considerations
    4. 7.4 Device Functional Modes
      1. 7.4.1 Device I/O Schematics
  9. Application and Implementation
    1. 8.1 Application Information
    2. 8.2 Typical Application
      1. 8.2.1 Design Requirements
      2. 8.2.2 Detailed Design Procedure
      3. 8.2.3 Application Curves
        1. 8.2.3.1 Insulation Lifetime
  10. Power Supply Recommendations
  11. 10Layout
    1. 10.1 Layout Guidelines
      1. 10.1.1 PCB Material
    2. 10.2 Layout Example
  12. 11Device and Documentation Support
    1. 11.1 Documentation Support
      1. 11.1.1 Related Documentation
    2. 11.2 Receiving Notification of Documentation Updates
    3. 11.3 Community Resources
    4. 11.4 Trademarks
  13. 12Revision History
  14. 13Mechanical, Packaging, and Orderable Information

Revision History

Changes from Revision G (June 2023) to Revision H (January 2024)

  • Updated numbering format for tables, figures and cross-references throughout documentGo
  • Updated Thermal Characteristics, Safety Limiting Values, and Thermal Derating Curves to provide more accurate system-level thermal calculationsGo
  • Updated electrical and switching characteristics to match device performanceGo

Changes from Revision F (November 2022) to Revision G (June 2023)

  • Changed standard name From: "DIN V VDE V 0884-11:2017-01" To: "DIN EN IEC 60747-17 (VDE 0884-17)" throughout the documentGo
  • Removed references to standard IEC/EN/CSA 60950-1 throughout the documentGo
  • Removed standard revision and year references from all standard names throughout the documentGo
  • Added Maximum impulse voltage (VIMP) per DIN EN IEC 60747-17 (VDE 0884-17) Go
  • Changed test conditions and values of Maximum surge isolation voltage (VIOSM) specification per DIN EN IEC 60747-17 (VDE 0884-17) Go
  • Clarified method b test conditions of Apparent charge (qPDGo
  • Changed maximum working voltage value From: 250 VRMS To: 400 VRMS for DBQ-16 devices per GB 4943.1Go
  • Changed working voltage lifetime margin from: 87.5% to: 50%, minimum required insulation lifetime from: 37.5 years to: 30 years and insulation lifetime per TDDB from: 135 years to: 169 years per DIN EN IEC 60747-17 (VDE 0884-17)Go
  • Changed Figure 8-7 per DIN EN IEC 60747-17 (VDE 0884-17)Go

Changes from Revision E (February 2019) to Revision F (November 2022)

  • Updated the numbering format for tables, figures, and cross-references throughout the documentGo

Changes from Revision D (November 2018) to Revision E (February 2019)

  • Changed CPG parameter description from "External clearance" to "External creepage"Go

Changes from Revision C (January 2018) to Revision D (November 2018)

  • Made editorial and cosmetic changes throughout the documentGo
  • Changed From: "Isolation Barrier Life: >40 Years" To:">100-Year Projected Lifetime" in Section 1 Go
  • Added "Up to 5000 VRMS Isolation Rating" in Section 1 Go
  • Added "Up to 12.8 kV Surge Capability" in Section 1 Go
  • Added "±8 kV IEC 61000-4-2 Contact Discharge Protection across Isolation Barrier" in Section 1 Go
  • Added "Automotive Version Available: ISO776x-Q1" in Section 1 Go
  • Deleted "Certification Planned" statement throughout the document Go
  • Updated Section 2 listGo
  • Changed Figure 3-1 to show series isolation capacitorsGo
  • Added table note to Data rate specificationGo
  • Changed VIORM value for DW-16 package from "1414 VPK" to "2121 VPK Go
  • Changed VIOWM values for DW-16 package from "1000 VRMS" and "1414 VDC" to "1500 VRMS" and "2121 VDC"Go
  • Updated certification informationGo
  • Changed From: "Table 2" To: "Safety Related Certifications" in Table 7-1 table noteGo
  • Changed Figure 7-3 Go
  • Added Section 8.2.3.1 sub-section under Section 8.2.3 sectionGo

Changes from Revision B (November 2017) to Revision C (January 2018)

  • Changed the CIO value for the DBQ package from 1.1 to 0.9 pFGo

Changes from Revision A (August 2017) to Revision B (November 2017)

  • Changed the CSA certification wording in the Features and Safety-Related Certifications tableGo
  • Changed the isolation voltage for the DBQ-16 package from 2500 to 3000 VRMS Go
  • Added the maximum transient isolation voltage for the DW-16 package of the ISO7761, ISO7762, and ISO7763 devices and changed the maximum value for the DBQ-16 package from 3600 to 4242 for all devicesGo
  • Changed table note and table condition of safety limiting valuesGo
  • Added the supply current vs data rate graphs for the ISO7761, ISO7762, and ISO7763 in the Typical Characteristics sectionGo

Changes from Revision * (August 2017) to Revision A (August 2017)

  • Deleted EN from the Common-Mode Transient Immunity Test Circuit figureGo
  • Changed the VCC1 and VCC2 signals in the Typical ISO7761 Circuit Hook-up figureGo