Since circuit noise on the analog power terminals must be minimized, an appropriate LC type filter is recommended for each supply. For EMI concerns, appropriate ferrite beads should be used instead of inductors in the LC filter circuit.
Analog power terminals should have a 0.1-µF bypass capacitor connected to VSS (ground) in order for proper operation. Place the capacitor as close as possible to the terminal on the device and keep the traces as short and wide as possible to the vias that are used to connect to the power planes. Smaller value capacitors like 0.01 µF are also recommended on the analog supply terminals.
Analog power terminals should have a 0.1-µF bypass capacitor connected to VSS (ground) in order for proper operation. Place the capacitor as close as possible to the terminal on the device and keep the traces as short and wide as possible to the vias that are used to connect to the power planes. Smaller value capacitors like 0.01 µF are also recommended on the analog supply terminals.