SLLU326A May 2022 – June 2022 TLIN1431-Q1
To activate the internal VBAT voltage divider on the TLIN1431-Q1, apply a high signal on DIV_ON using the appropriate pin on J4. By default, an internal pull-down deactivates the internal voltage divider when the pin is left floating.
The output of the voltage divider can be measured on PV.