SLLU363 may 2023 MCF8315A
For applications that require slow and gradual startup with lower speed overshoots during handoff, follow the below recommendations.
Step 1: Decrease Open loop acceleration coefficient A1 [OL_ACC_A1] and Open loop acceleration coefficient A2 [OL_ACC_A2].
Step 2: Enable Iq ramp down after transition to closed loop [IQ_RAMP_EN]
If there is speed overshoots, it is recommended to decrease ramp rate for reducing difference between estimated theta and open loop theta [THETA_ERROR_RAMP_RATE].