This fault gets triggered when motor speed
exceeds abnormal speed threshold [LOCK_ABN_SPEED]. When this fault gets triggered, use the
following recommendations:
- Increase align time [ALIGN_TIME],
decrease slow first cycle frequency [SLOW_FIRST_CYC_FREQ], or increase the IPD current
threshold [IPD_CURR_THR] and IPD repeat times [IPD_REPEAT] depending on the start-up mode
selected.
- Decrease open loop acceleration A1
[OL_ACC_A1] and open loop acceleration A2 [OL_ACC_A2].
- Decrease closed loop acceleration
[CL_ACC].