SLOK017 June   2024 TLV1H103-SEP

PRODUCTION DATA  

  1.   1
  2. TLV1H103-SEP Single-Event Effects (SEE) Radiation Report
  3.   Trademarks
  4. Overview
  5. SEE Mechanisms
  6. Test Device and Test Board Information
  7. Irradiation Facility and Setup
  8. Results
    1. 6.1 Single Event Latchup (SEL) Results
    2. 6.2 Single Event Transient (SET) Results
  9. Summary
  10. SET Results Appendix
  11. Confidence Interval Calculations
  12. 10References

SET Results Appendix

TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 50.5MeV-cm2 / mg, Output High ConditionFigure 8-1 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 50.5MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 50.5MeV-cm2 / mg, Output High ConditionFigure 8-3 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 50.5MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 50.5MeV-cm2 / mg, Output High ConditionFigure 8-5 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 50.5MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 35.6MeV-cm2 / mg, Output High ConditionFigure 8-7 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 35.6MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 35.6MeV-cm2 / mg, Output High ConditionFigure 8-9 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 35.6MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 35.6MeV-cm2 / mg, Output High ConditionFigure 8-11 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 35.6MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 23.1MeV-cm2 / mg, Output High ConditionFigure 8-13 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 23.1MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 23.1MeV-cm2 / mg, Output High ConditionFigure 8-15 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 23.1MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 23.1MeV-cm2 / mg, Output High ConditionFigure 8-17 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 23.1MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 9.8MeV-cm2 / mg, Output High ConditionFigure 8-19 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 9.8MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 9.8MeV-cm2 / mg, Output High ConditionFigure 8-21 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 9.8MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Run 196, Event 1, 3.3V Supply, LETEFF = 9.8MeV-cm2 / mg, Output Low ConditionFigure 8-23 Run 196, Event 1, 3.3V Supply, LETEFF = 9.8MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Run 203, Event 1, 3.3V Supply, LETEFF = 5.3MeV-cm2 / mg, Output High ConditionFigure 8-25 Run 203, Event 1, 3.3V Supply, LETEFF = 5.3MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Run 204, Event 2, 5.5V Supply, LETEFF = 5.3MeV-cm2 / mg, Output High ConditionFigure 8-27 Run 204, Event 2, 5.5V Supply, LETEFF = 5.3MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 50.5MeV-cm2 / mg, Output Low ConditionFigure 8-2 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 50.5MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 50.5MeV-cm2 / mg, Output Low ConditionFigure 8-4 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 50.5MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 50.5MeV-cm2 / mg, Output Low ConditionFigure 8-6 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 50.5MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 35.6MeV-cm2 / mg, Output Low ConditionFigure 8-8 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 35.6MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 35.6MeV-cm2 / mg, Output Low ConditionFigure 8-10 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 35.6MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 35.6MeV-cm2 / mg, Output Low ConditionFigure 8-12 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 35.6MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 23.1MeV-cm2 / mg, Output Low ConditionFigure 8-14 Transient Event Magnitude Histogram, 2.4V Supply, LETEFF = 23.1MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 23.1MeV-cm2 / mg, Output Low ConditionFigure 8-16 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 23.1MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 23.1MeV-cm2 / mg, Output Low ConditionFigure 8-18 Transient Event Magnitude Histogram, 5.5V Supply, LETEFF = 23.1MeV-cm2 / mg, Output Low Condition
TLV1H103-SEP Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 9.8MeV-cm2 / mg, Output High ConditionFigure 8-20 Transient Event Magnitude Histogram, 3.3V Supply, LETEFF = 9.8MeV-cm2 / mg, Output High Condition
TLV1H103-SEP Run 34, Event 90, Zoomed inFigure 8-22 Run 34, Event 90, Zoomed in
TLV1H103-SEP Run 196, Event 1, Zoomed InFigure 8-24 Run 196, Event 1, Zoomed In
TLV1H103-SEP Run 203, Event 1, Zoomed InFigure 8-26 Run 203, Event 1, Zoomed In