SLOU441 July 2016 TPA3255
The TPA3255EVM can be configured for four different output operations. The 2.0 BTL configuration is the default set up of the TPA3255EVM described in Section 2.3. The remaining three configurations are 2.1 BTL plus two single-ended (SE) outputs, 0.1 PBTL output, and 4.0 single-ended (SE) outputs.
Mode Pins | Input Mode | Output Configuration | Description | |
---|---|---|---|---|
M2 | M1 | |||
0 | 0 | 2N + 1 | 2 × BTL | Stereo BTL output configuration |
0 | 1 | 2N/1N + 1 | 1 × BTL + 2 × SE | 2.1 BTL + SE mode |
1 | 0 | 2N + 1 | 1 × PBTL | Paralleled BTL configuration. Connect INPUT_C and INPUT_D to GND. |
1 | 1 | 1N + 1 | 4 × SE | Single-ended output configuration |