Termination Voltage (EDV) should be in the steep zone of the cell voltage profile. This will allow the simulation to terminate accurately and stable. If the EDV shifts into the flat zone, a small charge in simulated voltage can cause a big change in simulated capacity.
It is suggested to use lower EDV with some Reserve Capacity, instead of using high EDV. Reserve Capacity is to give the host system a buffer to make sure it shutdown properly without a sudden brownout.