SLUAAB9A March 2021 – December 2021 UCC25800-Q1
The LLC converter and flyback converter EMI performances are also measured when they are used to bias an inverter gate drivers. A half-bridge inverter design based on Recom Power inverter EVM R-REF01-HB was biased with an LLC converter and the flyback converter, respectively. The EMI noise is measured from the 24-V input side, and the inverter is powered through a high-voltage power supply with 400-V DC output. The inverter is switched at 20 kHz with 50% duty cycle with no load. The inverter creates high dv/dt through its switch node and coupled through the transformer parasitic capacitance. This coupled noise can be measured through the LISN connected at the 24-V input. The measurement setup is shown in Figure 8-4. Similar to the stand alone board setup, no EMI filter is used to measure the raw noise coming from the setup.
The measured EMI performances is summarized in Figure 8-5 and Figure 8-6. The noise floor is raised due to the noise generated by the inverter power stage. However, it can be observed that the LLC converter still provides much lower EMI noise performance comparing with flyback converter, especially at the higher frequency range.