When x-cap discharge is disabled,
this pin can be connected to either rectified AC or DC.
When x-cap discharge is enabled,
this pin can only be connected to rectified AC. Connecting this pin to DC might
not break the device, but the system will consume more power and might run into
over temperature protection
For debugging purpose, the current flowing into the HV pin can be measured by
the voltage across the HV pin series resistors.