SLUAAM9 November 2022 TPS56C230
OOB function is beneficial for the settle time during load transient. There could be a output overshoot when load current changes from high to low, as shown in Figure 4-1 and Figure 4-2. TPS56C230 with OOB function will turn on low-side FET to discharge output voltage, and its Vout becomes stable quicker than TPS51397A without OOB function. Test condition: 12Vin-1.2Vo-Eco mode-Load Transient 1-10A.