The device supports detection of broken connections between the chip and the battery. An open-wire event can occur by a physically broken connection between cells, a contaminated contact, wrong resistor values, or solder defect. In case of an open-wire event, the device can provide incorrect voltage measurements for that cell. During open-wire detection, a small amount of current flows from each cell to ground. If a cell is disconnected, the voltage at the measurement node then quickly drop triggering an undervoltage fault. Open-wire detection can be enabled in the Settings:Cell Open-Wire:Check Time register and set periodically so that the average current drawn is between 0.65nA to 165nA.