Apply a known temperature in 0.1°C, and verify that temperature Temp
TINT
is applied to the device.
Read the TINT offset
old
from
Internal Temp Offset
.
Read the reported temperature from
DAStatus2()
:
TINT = AAaa of
DAStatus2()
Is TINT > 0? If yes, TINT = AAaa – 2732.
Calculate temperature offset:
Equation 5.
T
I
N
T
o
f
f
s
e
t
=
T
E
M
P
T
I
N
T
-
T
I
N
T
+
T
I
N
T
o
f
f
s
e
t
o
l
d
Write the new
Internal Temp Offset
value to data flash.
Re-check the
DAStatus2()
reading. If the reading is not accurate, repeat steps 1 – 5.