SLUS987C January 2011 – December 2019 BQ33100
PRODUCTION DATA.
Entry and exit of each mode is controlled by data flash parameters. In DISCHARGE mode, the [DSG] flag in OperationStatus() is set. DISCHARGE mode is entered when Current goes below (–)Dsg Current Threshold. DISCHARGE mode is exited when Current goes above Chg Current Threshold threshold for more than 1 second.
CHARGE mode is entered when Current goes above Chg Current Threshold. CHARGE mode is exited when Current goes below Dsg Current Threshold for more than 1 second.