VFsecondary rectifier forward voltage drop at near-zero current.
VFAauxiliary rectifier forward voltage drop.
VLKestimated leakage inductance energy reset voltage.
VOCVregulated output voltage of the converter.
VOCCtarget lowest converter output voltage in constant-current regulation.
VOVLThe output voltage reaches VOVL when output current reaches its limit IOCC; VOVL is determined by IOCC and the expected minimum load resistance RLOAD at IOCC, i.e., VOVL = IOCC x RLOAD.
VRIPPLEoutput peak-to-peak ripple voltage at full-load.