SLUSDF5A
January 2019 – August 2019
TPS560430-Q1
PRODUCTION DATA.
1
Features
2
Applications
3
Description
Device Images
Simplified Schematic
Efficiency vs Output Current VOUT = 5 V, 2100 kHz, PFM
4
Revision History
5
Device Comparison Table
6
Pin Configuration and Functions
Pin Functions
7
Specifications
7.1
Absolute Maximum Ratings
7.2
ESD Ratings
7.3
Recommended Operating Conditions
7.4
Thermal Information
7.5
Electrical Characteristics
7.6
Timing Requirements
7.7
Switching Characteristics
7.8
Typical Characteristics
8
Detailed Description
8.1
Overview
8.2
Functional Block Diagram
8.3
Feature Description
8.3.1
Fixed Frequency Peak Current Mode Control
8.3.2
Adjustable Output Voltage
8.3.3
Enable
8.3.4
Minimum ON-Time, Minimum OFF-Time and Frequency Foldback
8.3.5
Bootstrap Voltage
8.3.6
Over Current and Short Circuit Protection
8.3.7
Soft Start
8.3.8
Thermal Shutdown
8.4
Device Functional Modes
8.4.1
Shutdown Mode
8.4.2
Active Mode
8.4.3
CCM Mode
8.4.4
Light-Load Operation (PFM Version)
8.4.5
Light-Load Operation (FPWM Version)
9
Application and Implementation
9.1
Application Information
9.2
Typical Application
9.2.1
Design Requirements
9.2.2
Detailed Design Procedure
9.2.2.1
Custom Design With WEBENCH® Tools
9.2.2.2
Output Voltage Set-Point
9.2.2.3
Switching Frequency
9.2.2.4
Inductor Selection
9.2.2.5
Output Capacitor Selection
9.2.2.6
Input Capacitor Selection
9.2.2.7
Bootstrap Capacitor
9.2.2.8
Under Voltage Lockout Set-Point
9.2.3
Application Curves
10
Power Supply Recommendations
11
Layout
11.1
Layout Guidelines
11.1.1
Compact Layout for EMI Reduction
11.1.2
Feedback Resistors
11.2
Layout Example
12
Device and Documentation Support
12.1
Device Support
12.1.1
Development Support
12.1.1.1
Custom Design With WEBENCH® Tools
12.2
Documentation Support
12.2.1
Related Documentation
12.3
Receiving Notification of Documentation Updates
12.4
Community Resources
12.5
Trademarks
12.6
Electrostatic Discharge Caution
12.7
Glossary
13
Mechanical, Packaging, and Orderable Information
7.2
ESD Ratings
VALUE
UNIT
V
(ESD)
Electrostatic discharge
Human-body model (HBM), per AEC Q100-002
(1)
±2500
V
Charged-device model (CDM), per AEC Q100-011
±750
(1)
AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification.