Typical values stated where TA = 25°C and
VBAT = 14.4V, Min/Max values stated where TA = –40°C
to 85°C and VBAT = 3.0V to 28V (unless otherwise noted)(1)
PARAMETER |
TEST
CONDITIONS |
MIN |
TYP |
MAX |
UNIT |
IACTIVE(2) |
ACTIVE mode |
No Flash write |
|
190 |
|
µA |
ISLEEP(3) |
SLEEP mode |
No SBS
communication |
|
72 |
|
µA |
ISHUTDOWN |
SHUTDOWN mode |
|
|
1.4 |
|
µA |
(1) Specified by design. Not production tested.
(2) Assuming device is running
typical firmware settings under NORMAL mode, which manges CPU and ADC/CC duty
cycle to <4%
(3) Assuming device is running
typical firmware settings under SLEEP mode, which manges CPU and CC duty cycle
to <1%