SLUSFF2 October 2024 UCG28826
ADVANCE INFORMATION
The regulatory standards require the flyback converter output current and output power to not exceed 8A and 100W, respectively after 5s. The UCG28826 triggers over power protection (low, OPPL) for input power greater than 90W and/or output current (input referred) larger than 7A for longer than 4.2s duration, to prevent from excessive power delivery to the output in fault conditions. The device also supports transient load requirements of min. 2x the nominal output power rating (130W for 65W design) for upto 80ms beyond which over power protection (high, OPPH) is triggered. The device will work in CCM mode for VBULK <200V for a max. 4ms duration.