SLUSFM4 September 2024 LMR51425 , LMR51435
PRODUCTION DATA
Continuous Conduction Mode (CCM) operation is employed in the LMR514x5 when the load current is greater than half of the peak-to-peak inductor current. In CCM operation, the frequency of operation is fixed, output voltage ripple is at a minimum in this mode, and the maximum output current of 2.5A or 3.5A can be supplied by the LMR51425 or LMR51435 respectively.