Figure 5-2 is the basic test setup recommended for evaluating the TPS40100EVM-001. The EVM
is shipped with the following in the default position:
- The enable switch (S1) is open
across pins 2 and 3. This is the enable position.
- The tracking enable jumper (J8)
has shunt positioned across pins 1 and 2, disabling the tracking feature.
- The tracking engage switch (S2)
is open across pins 2 and 3. This enables the tracking ramp to charge.
- Remote sense jumpers (J6 and J7)
have shunts positioned across pins 2 and 3, enabling local connector
sensing.
- Margin shunts positioned in the
margin disable position.