The TPS40195EVM defaults to the Enabled state.
- Set up the EVM as described in Section 5.2 and Figure 5-1.
- Using a four-channel oscilloscope monitor TP11,
TP9, and TP5.
- Increase VIN to 8 V.
- Set LOAD1 to 10 A.
- Short TP11 to TP2. Output should drop to
zero.
- Remove short. Output should return to
regulation.
- Repeat steps 4 and 5 above for various
VIN and LOAD1 combinations.
- See Section 6.6 for equipment shutdown.
See Section 7.6 for typical disable and power good performance.