SLUU818A April 2012 – February 2022 TPS51219
Voltage Source VIN: The input voltage source VIN must be a 0-V to 20-V variable DC source capable of supplying 10 ADC. Connect VIN to J4 as shown in Figure 4-2.
Voltage Source V5IN: The input voltage source V5IN must be a 0-V to 5-V variable DC source capable of supplying 1 ADC. Connect V5IN to J1 as shown in Figure 4-2.
Multimeters:
Output Load: The output load must be an electronic constant-resistance mode load capable of 0 ADC to 30 ADC at 1.05 V.
Oscilloscope: A digital or analog oscilloscope can be used to measure the output ripple. The oscilloscope must be set for the following:
Test point J6 can be used to measure the differential output ripple voltage, using a passive probe with the shortest leaded ground clip. For switch node voltage measurement, TP7 and TP8 can be used by placing the passive probe tip through TP7 and holding the ground barrel TP8 as shown in Figure 4-1. In this case, using a leaded ground connection may induce additional noise due to the large ground loop.
Fan: Some of the components in this EVM can get hot, approaching temperatures of 60°C during operation. A small fan capable of 200–400 LFM is recommended to reduce component temperatures while the EVM is operating. The EVM must not be probed when the fan is not running.
Recommended Wire Gauge: