SLUUA65E april 2014 – june 2023 BQ28Z610
This command returns the ManufacturingStatus() flags on MACData().
Status | Condition | Action |
---|---|---|
Activate | 0x0057 to AltManufacturerAccess() | Outputs ManufacturingStatus() flags on MACData() |
15 | 14 | 13 | 12 | 11 | 10 | 9 | 8 |
CAL_EN | RSVD | RSVD | RSVD | RSVD | RSVD | RSVD | RSVD |
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RSVD | PF_EN | LF_EN | FET_EN | GAUGE_EN | DSG_TEST | CHG_TEST | RSVD |
CAL_EN (Bit 15): CALIBRATION Mode | ||
1 = | Enabled | |
0 = | Disabled | |
RSVD (Bits 14–7): Reserved | ||
PF_EN (Bit 6): Permanent Failure | ||
1 = | Enabled | |
0 = | Disabled | |
LF_EN (Bit 5): Lifetime Data Collection | ||
1 = | Enabled | |
0 = | Disabled | |
FET_EN (Bit 4): All FET Action | ||
1 = | Enabled | |
0 = | Disabled | |
GAUGE_EN (Bit 3): Gas Gauging | ||
1 = | Enabled | |
0 = | Disabled | |
DSG_TEST (Bit 2): Discharge FET Test | ||
1 = | Discharge FET test activated | |
0 = | Disabled | |
CHG_TEST (Bit 1): Charge FET Test | ||
1 = | Charge FET test activated | |
0 = | Disabled | |
RSVD (Bit 0): Reserved |