SLUUA65E april 2014 – june 2023 BQ28Z610
This command instructs the device to return Impedance Track related gauging information on MACData().
Status | Condition | Action |
---|---|---|
Activate | 0x0073 to AltManufacturerAccess() | Outputs 24 bytes of IT data values on MACData() in the following format: aaAAbbBBccCCddDDeeEEffFFggGGhhHHiiIIjjJJkkKKllLL where: AAaa: True Rem Q. True remaining capacity in mAh from IT simulation before any filtering or smoothing function. This value can be negative or higher than FCC. BBbb: True Rem E. True remaining energy in cWh from IT simulation before any filtering or smoothing function. This value can be negative or higher than FCC. CCcc: Initial Q. Initial capacity calculated from IT simulation DDdd: Initial E. Initial energy calculated from IT simulation EEee: TrueFullChgQ. True full charge capacity FFff: TrueFullChgE. True full charge energy GGgg: T_sim. Temperature during the last simulation run (in 0.1K) HHhh: T_ambient. Current estimated ambient temperature used by the IT algorithm for thermal modeling IIii: RaScale 0. Ra table scaling factor of Cell1 JJjj: RaScale 1. Ra table scaling factor of Cell2 KKkk: CompRes1. Last computed resistance for Cell1 LLll: CompRes2. Last computed resistance for Cell2 |