SLUUA65E april 2014 – june 2023 BQ28Z610
The BQ28Z610 device can disable charging if certain safety conditions are detected, setting the OperationStatus()[XCHG] = 0.
Status | Condition | Action |
---|---|---|
Normal | SafetyStatus()[COV] = 0 AND SafetyStatus()[OCC] = 0,0 AND SafetyStatus()[ASCC] = 0 AND AND SafetyStatus()[CTO] = 0 AND SafetyStatus()[PTO] = 0 AND GaugingStatus()[TCA] = 0 if Charging Configuration[CHGFET] = 1 | ChargingVoltage() = Charging Algorithm ChargingCurrent() = Charging Algorithm OperationStatus()[XCHG] = 0 |
Trip | ManufacturingStatus()[FET_EN] = 0 OR SafetyStatus()[COV] = 1 OR SafetyStatus()[OCC] = 1 OR SafetyStatus()[ASCC] = 1 OR SafetyStatus()[CTO] = 1 OR SafetyStatus()[PTO] = 1 OR SafetyStatus()[OC] = 1 OR SafetyStatus()[UTC] = 1 OR SafetyStatus()[OTC] = 1 if ChargingStatus()[IN] = 1 if [CHGIN] = 1 OR ChargingStatus()[SU] = 1 if [CHGSU] = 1 OR OperationStatus()[SLEEP] = 1 if AND [SLEEPCHG] = 0 OR GaugingStatus()[TCA] = 1 if Charging Configuration[CHGFET] = 1 | ChargingVoltage() = 0 ChargingCurrent() = 0 OperationStatus()[XCHG] = 1 |
Similarly, the device can disable discharge of certain safety conditions if any of the following conditions are detected, setting the OperationStatus()[XDSG] = 1: