SLUUAQ3A April 2016 – October 2022 BQ4050
The device can detect an external trigger of the chemical fuse by an external protection circuit such as a 2nd-level protector by monitoring the FUSE pin state.
If the device detects a FUSE pin high state, the CHG and DSG FETs are turned off.
Setting Enabled PF C[2LVL] = 0 will not prevent the second level protector from triggering and blowing the fuse, setting [2LVL] = 0 will only prevent the gauge from detecting the fuse state.
Status | Condition | Action |
---|---|---|
Normal | Reset AFE and FUSE pin = low AND No FUSE trigger by firmware | PFAlert()[2LVL] = 0 |
Alert | FUSE pin = high AND No FUSE trigger by firmware | PFAlert()[2LVL] = 1 Reset AFE FUSE bit |
Trip | FUSE pin continuously high for 2LVL:Delay period AND No FUSE trigger by firmware | PFAlert()[2LVL] = 0 PFStatus()[2LVL] = 1 |