SLUUAQ3A April 2016 – October 2022 BQ4050
Class | Subclass | Name | Type | Min | Max | Default | Unit |
---|---|---|---|---|---|---|---|
Settings | Configuration | SBS Gauging Configuration | H1 | 0x00 | 0xFF | 0x04 | Hex |
7 | 6 | 5 | 4 | 3 | 2 | 1 | 0 |
RSVD | RSVD | RSVD | RSVD | RSVD | LOCK0 | RSVD | RSOCL |
RSVD (Bits 7–3): Reserved. Do not use. | ||
LOCK0 (Bit 2): Keep RemainingCapacity() and RelativeStateOfCharge() jumping back during relaxation after 0 was reached during discharge. | ||
1 = | Enabled (default) | |
0 = | Disabled | |
RSVD (Bit 1): Reserved. Do not use. | ||
RSOCL (Bit 0): RelativeStateOfCharge() and RemainingCapacity() behavior at end of charge | ||
1 = | Held at 99% until valid charge termination. On entering valid charge termination, updates to 100% | |
0 = | Actual value shown (default) |