SLUUAV7C December   2013  – November 2022 BQ40Z50 , BQ40Z50-R2

 

  1.   Abstract
  2.   Trademarks
  3. 1Features
    1. 1.1 Kit Contents
    2. 1.2 Ordering Information
    3. 1.3 Documentation
    4. 1.4 bq40z50 and bq296000 Circuit Module Performance Specification Summary
  4. 2bq40z50EVM Quick Start Guide
    1. 2.1 Items Needed for EVM Setup and Evaluation
    2. 2.2 Software Installation
    3. 2.3 EVM Connections
    4. 2.4 Update Firmware
  5. 3Battery Management Studio
    1. 3.1 Registers Screen
    2. 3.2 Setting Programmable bq40z50 Options
    3. 3.3 Calibration Screen
      1. 3.3.1 Voltage Calibration
      2. 3.3.2 Temperature Calibration
      3. 3.3.3 Current Calibration
    4. 3.4 Chemistry Screen
    5. 3.5 Firmware Screen
      1. 3.5.1 Programming the Flash Memory
      2. 3.5.2 Exporting the Flash Memory
    6. 3.6 Advanced Comm SMB Screen
  6. 4bq40z50EVM Circuit Module Schematic
    1. 4.1 Pre-Charge
    2. 4.2 LED Control
    3. 4.3 Emergency Shutdown
    4. 4.4 Testing Fuse-Blowing Circuit
    5. 4.5 PTC Thermistor
  7. 5Circuit Module Physical Layouts
    1. 5.1 Board Layout
    2. 5.2 Schematic
  8. 6Bill of Materials
  9. 7Related Documentation from Texas Instruments
  10. 8Revision History

Voltage Calibration

  • Measure the voltage from Cell 1 to 1N and enter this value in the Applied Cell 1 Voltage field and select the Calibrate Voltage box.
  • Measure the voltage from Bat+ to Bat– and enter this value in the Applied Battery Voltage field and select the Calibrate Battery Voltage box.
  • Measure the voltage from Pack+ to Pack– and enter this value in the Applied Pack Voltage field and select the Calibrate Pack Voltage box. If the voltage is not present, then turn the charge and discharge FETs on by entering a 0x0022 command in the Manufacturer Access register on the Register screen.
  • Press the Calibrate Gas Gauge button to calibrate the voltage measurement system.
  • Deselect the Calibrate Voltage boxes after voltage calibration has completed.