SLUUB41A May 2014 – October 2021 BQ76920 , BQ76930 , BQ76940
For the BQ76920, yes, a hold-up circuit can be used to maintain a voltage above VSHUT during heavy pack loads.
Similarly a hold-up circuit can be used on REGSRC to maintain voltage for FET drive and REGOUT. Because the FET drive comes from REGSRC also, realize the FET drive voltage will drop before the REGOUT voltage. Be sure to size the circuit components and set protection delays to maintain an adequate FET drive voltage with maximum REGOUT load.
For the BQ76930 and BQ76940, a hold-up circuit on BAT is not suitable. Implementing a hold-up circuit on BAT, VC10X, or VC5X may cause device absolute maximum limits to be exceeded and may result in device damage. For these devices, set the protection thresholds and timing to provide protection while the part has adequate power. Refer to section 9 the BQ769x0 Family Top 10 Design Considerations application report for more details.