SLUUBD4A April 2016 – November 2022 BQ27220
The BQ27220 device monitors the battery for three low-voltage thresholds: EDV0, EDV1, and EDV2.
If the [EDV_CMP] bit in CEDV Gauging Configuration is clear, fixed EDV thresholds may be programmed in Fixed EDV0, Fixed EDV1, and Fixed EDV2 in mV.
If the [EDV_CMP] bit in CEDV Gauging Configuration is set, automatic EDV compensation is enabled and the BQ27220 device computes the EDV0, EDV1, and EDV2 thresholds based on values stored in the selected CEDV profile in data flash and the battery's current discharge rate and temperature. If the [FIXED_EDV0] bit in CEDV Gauging Configuration is also set, then the EDV0 threshold will be set to the programmed Fixed EDV0, and the EDV1 and EDV2 compensated thresholds will not go below the programmed Fixed EDV0.
The BQ27220 device disables EDV detection if Current exceeds the Overload Current threshold. The BQ27220 device resumes EDV threshold detection after Current drops below the Overload Current threshold. Any EDV threshold detected is reset after charge is applied and [VDQ] is cleared after 10 mAh of charge.
The BQ27220 device uses the EDV thresholds to apply voltage-based corrections to the RM register (see Table 2-1).
THRESHOLD | RELATIVE STATE OF CHARGE |
---|---|
EDV0 | 0% |
EDV1 | 3% |
EDV2 | Battery Low % |
The BQ27220 device performs EDV-based RM adjustments with Current ≥ C/32. No EDVs are set if Current < C/32. The BQ27220 device adjusts RM as it detects each threshold. If the voltage threshold is reached before the corresponding capacity on discharge, the BQ27220 device reduces RM to the appropriate amount as shown in Table 2-1.
If an RM % level is reached on discharge before the voltage reaches the corresponding threshold, then RM is held at that % level until the threshold is reached. RM is only held if [VDQ] = 1, indicating a valid learning cycle is in progress. If Battery Low % is set to zero, EDV1 and EDV0 corrections are disabled.