SLUUBD4A April 2016 – November 2022 BQ27220
This value is updated by the CEDV gauging algorithm when battery voltage reaches EDV2. If Battery Low % is altered, the DOD at EDV2 value should be set to (1 – Battery_Low%) × 16384, where Battery_Low% = Battery Low % ÷ 100. The firmware default value is 15232, which corresponds to a Battery Low % = 703 (.01 %).