SLUUBD4A April 2016 – November 2022 BQ27220
The BQ27220 device enters RELAXATION mode from CHARGE mode if Current() goes below Quit Current for Chg Relax Time. The device enters RELAXATION mode from DISCHARGE mode if Current() goes above (–)Quit Current for Dsg Relax Time. The default value is 40 mA.