SLUUBD4A April 2016 – November 2022 BQ27220
Various gas gauging features can be configured by the CEDV Gauging Configuration register.
Feature | Description | |
---|---|---|
FCC_LIMIT | The FCC_LIMIT bit selects whether FCC limit can go above Design Capacity mAh. | |
0 = | FCC can learn above Design Capacity mAh. | |
1 = | FCC is limited to Design Capacity mAh. | |
SC | The SC bit enables learning cycle optimization for a Smart Charger or independent charge. | |
0 = | Learning cycle is optimized for Smart Charger. | |
1 = | Learning cycle is optimized for independent charger. | |
EDV_CMP | The EDV_CMP bit determines whether the BQ27220 device implements automatic EDV compensation to calculate the EDV0, EDV1, and EDV2 thresholds based on rate, temperature, and capacity. If the bit is cleared, the BQ27220 device uses the fixed values programmed in data flash for EDV0, EDV1, and EDV2. If the bit is set, the BQ27220 device calculates EDV0, EDV1, and EDV2. | |
0 = | EDV compensation is disabled. | |
1 = | EDV compensation is enabled. | |
FIXED_EDV0 | The FIXED_EDV0 bit selects whether EDV0 is always fixed. | |
0 = | EDV0 is determined based on the [EDV_CMP] bit. | |
1 = | EDV0 will always use Fixed EDV0. EDV1 and EDV2 compensation will not go below Fixed EDV0. | |
CSYNC | The CSYNC bit selects whether RM is set to FCC at charge termination. | |
0 = | RM is not changed when charge termination is reached. | |
1 = | RM will be set to FCC when charge termination is reached. |