SLUUBT5C November 2018 – June 2021 BQ40Z80
The BQ40Z80 device can permanently disable the battery in the case of significant overcurrent in the DISCHARGE or RELAX state.
Status | Condition | Action |
---|---|---|
Normal | Current() > SOCD:Threshold | PFAlert()[SOCD] = 0 |
Alert | Current() ≤ SOCD:Threshold | PFAlert()[SOCD] = 1 BatteryStatus()[TDA] = 1 |
Trip | Current() ≤ SOCD:Threshold for SOCD:Delay duration | PFAlert()[SOCD] = 1 PFStatus()[SOCD] = 1 |