SLUUBT5C November 2018 – June 2021 BQ40Z80
This command instructs the device to return cell balance time information on ManufacturerBlockAccess() or ManufacturerData().
Status | Condition |
---|---|
Activate | 0x0076 to ManufacturerBlockAccess() or ManufacturerAccess() |
Action: Output 30 bytes of cell balance data values on ManufacturerBlockAccess() or ManufacturerData() in the following format: aaAAbbBBccCCddDDeeEEffFFggGGhhHHiiIIjjIIkkKKllLLmmMMnnNNooOO where:
Value | Description | Unit |
---|---|---|
AAaa | Cell balance time 0. Calculated cell balancing time of Cell 1 | s |
BBbb | Cell balance time 1. Calculated cell balancing time of Cell 2 | s |
CCcc | Cell balance time 2. Calculated cell balancing time of Cell 3 | s |
DDdd | Cell balance time 3. Calculated cell balancing time of Cell 4 | s |
EEee | Cell balance time 4. Calculated cell balancing time of Cell 5 | s |
FFff | Cell balance time 5. Calculated cell balancing time of Cell 6 | s |
GGgg | Cell balance time 6. Calculated cell balancing time of Cell 7 | s |
HHhh | DOD used to calculate cell 1 balance time | — |
IIii | DOD used to calculate cell 2 balance time | — |
JJjj | DOD used to calculate cell 3 balance time | — |
KKkk | DOD used to calculate cell 4 balance time | — |
LLll | DOD used to calculate cell 5 balance time | — |
MMmm | DOD used to calculate cell 6 balance time | — |
NNnn | DOD used to calculate cell 7 balance time | — |
OOoo | Total DOD charge | — |