SLUUBT5C November 2018 – June 2021 BQ40Z80
The BQ40Z80 device can permanently disable the battery in the case of significant undervoltage in any of the cells.
Status | Condition | Action |
---|---|---|
Normal | Min cell voltage1..7 > SUV:Threshold | PFAlert()[SUV] = 0 BatteryStatus()[TDA] = 0 |
Alert | Min cell voltage1..7 ≤ SUV:Threshold | PFAlert()[SUV] = 1 BatteryStatus()[TDA] = 1 |
Trip | Min cell voltage1..7 continuous ≤ SUV:Threshold for SUV:Delay duration | PFAlert()[SUV] = 0 PFStatus()[SUV] = 1 BatteryStatus()[FD] = 1 |