SLUUBT5C November 2018 – June 2021 BQ40Z80
If [LEDPF1, LEDPF0] = 0,1, then the LED display shows each PF code for 2 × the LED Hold Time after showing the state-of-charge information.
The following table shows each PF error code. Each code is shown with the lowest to highest priority order.
PF Flag | Priority | LED3 | LED2 | LED1 |
---|---|---|---|---|
No PF | 0 | LED Blink Period | off | off |
SUV | 0 | LED Blink Period | on | off |
SOV | 1 | LED Blink Period | LED Flash Period | off |
SOCC | 2 | LED Blink Period | off | on |
SOCD | 3 | LED Blink Period | on | on |
SOT | 4 | LED Blink Period | LED Flash Period | on |
COVL | 5 | LED Blink Period | off | LED Flash Period |
SOTF | 6 | LED Blink Period | on | LED Flash Period |
QIM | 7 | LED Blink Period | LED Flash Period | LED Flash Period |
CB | 8 | LED Blink Period | off | LED Blink Period |
IMP | 9 | LED Blink Period | on | LED Blink Period |
CD | 10 | LED Flash Period | LED Blink Period | off |
VIMR | 11 | off | LED Blink Period | off |
VIMA | 12 | on | LED Blink Period | off |
OLDL | 13 | LED Flash Period | LED Blink Period | on |
SCCL | 14 | off | LED Blink Period | on |
SCDL | 15 | on | LED Blink Period | on |
CFETF | 16 | LED Flash Period | LED Blink Period | LED Flash Period |
DFETF | 17 | off | LED Blink Period | LED Flash Period |
OCDL | 18 | on | LED Blink Period | LED Flash Period |
FUSE | 19 | LED Flash Period | LED Blink Period | LED Blink Period |
AFER | 20 | off | LED Blink Period | LED Blink Period |
AFEC | 21 | on | off | LED Blink Period |
2LVL | 22 | LED Flash Period | off | LED Blink Period |
PTC | 23 | off | off | LED Blink Period |
IFC | 24 | on | on | LED Blink Period |
DF | 26 | off | on | LED Blink Period |
Reserved | 27 | on | LED Flash Period | LED Blink Period |
Open Therm TS1 | 28 | LED Flash Period | LED Flash Period | LED Blink Period |
Open Therm TS2 | 29 | off | LED Flash Period | LED Blink Period |
Open Therm TS3 | 30 | on | LED Blink Period | LED Blink Period |
Open Therm TS4 | 31 | LED Flash Period | LED Blink Period | LED Blink Period |
If [LEDPF1, LEDPF0] = 1,0, then under PF conditions, if the DISP button is pressed (high-to-low transition of the DISP pin is detected), the LED display immediately shows each PF code for 2 × the LED Hold Time (without showing the state-of-charge information).