SLUUBW5A July 2018 – September 2021 BQ34Z100-G1
Table 8-1 summarizes the data flash locations available to the user, including the default, minimum, and maximum values.
CLASS | SUBCLASS | SUBCLASS ID | OFFSET | TYPE | NAME | MIN | MAX | DEFAULT | UNIT |
---|---|---|---|---|---|---|---|---|---|
Configuration | Safety | 2 | 0 | I2 | OT Chg | 0 | 1200 | 550 | 0.1°C |
Configuration | Safety | 2 | 2 | U1 | OT Chg Time | 0 | 60 | 2 | s |
Configuration | Safety | 2 | 3 | I2 | OT Chg Recovery | 0 | 1200 | 500 | 0.1°C |
Configuration | Safety | 2 | 5 | I2 | OT Dsg | 0 | 1200 | 600 | 0.1°C |
Configuration | Safety | 2 | 7 | U1 | OT Dsg Time | 0 | 60 | 2 | s |
Configuration | Safety | 2 | 8 | I2 | OT Dsg Recovery | 0 | 1200 | 550 | 0.1°C |
Configuration | Charge Inhibit Cfg | 32 | 0 | I2 | Chg Inhibit Temp Low | –400 | 1200 | 0 | 0.1°C |
Configuration | Charge Inhibit Cfg | 32 | 2 | I2 | Chg Inhibit Temp High | –400 | 1200 | 450 | 0.1°C |
Configuration | Charge Inhibit Cfg | 32 | 4 | I2 | Temp Hys | 0 | 100 | 50 | 0.1°C |
Configuration | Charge | 34 | 0 | I2 | Suspend Low Temp | –400 | 1200 | –50 | 0.1°C |
Configuration | Charge | 34 | 2 | I2 | Suspend High Temp | –400 | 1200 | 550 | 0.1°C |
Configuration | Charge | 34 | 4 | U1 | Pb EFF Efficiency | 0 | 100 | 100 | % |
Configuration | Charge | 34 | 5 | F4 | Pb Temp Comp | 0 | 0.078125 | 0.01953125 | % |
Configuration | Charge | 34 | 9 | U1 | Pb Drop Off Percent | 0 | 100 | 96 | % |
Configuration | Charge | 34 | 10 | F4 | Pb Reduction Rate | 0 | 1.25 | 0.125 | % |
Configuration | Charge Termination | 36 | 0 | I2 | Taper Current | 0 | 1000 | 100 | mA |
Configuration | Charge Termination | 36 | 2 | I2 | Min Taper Capacity | 0 | 1000 | 25 | mAh |
Configuration | Charge Termination | 36 | 4 | I2 | Cell Taper Voltage | 0 | 1000 | 100 | mV |
Configuration | Charge Termination | 36 | 6 | U1 | Current Taper Window | 0 | 60 | 40 | s |
Configuration | Charge Termination | 36 | 7 | I1 | TCA Set % | –1 | 100 | 99 | % |
Configuration | Charge Termination | 36 | 8 | I1 | TCA Clear % | –1 | 100 | 95 | % |
Configuration | Charge Termination | 36 | 9 | I1 | FC Set % | –1 | 100 | 100 | % |
Configuration | Charge Termination | 36 | 10 | I1 | FC Clear % | –1 | 100 | 98 | % |
Configuration | Charge Termination | 36 | 11 | I2 | DODatEOC Delta T | 0 | 1000 | 100 | 0.1°C |
Configuration | Charge Termination | 36 | 13 | I2 | NiMH Delta Temp | 0 | 255 | 30 | 0.1°C |
Configuration | Charge Termination | 36 | 15 | U2 | NiMH Delta Temp Time | 0 | 1000 | 180 | s |
Configuration | Charge Termination | 36 | 17 | U2 | NiMH Hold Off Time | 0 | 1000 | 100 | s |
Configuration | Charge Termination | 36 | 19 | I2 | NiMH Hold Off Current | 0 | 32000 | 240 | mA |
Configuration | Charge Termination | 36 | 21 | I2 | NiMH Hold Off Temp | 0 | 1000 | 250 | 0.1°C |
Configuration | Charge Termination | 36 | 23 | U1 | NiMH Cell Negative Delta Volt | 0 | 100 | 17 | mV |
Configuration | Charge Termination | 36 | 24 | U1 | NiMH Cell Negative Delta Time | 0 | 255 | 16 | s |
Configuration | Charge Termination | 36 | 25 | I2 | NiMH Cell Neg Delta Qual Volt | 0 | 32767 | 4200 | mV |
Configuration | Data | 48 | 2 | U2 | Manufacture Date | 0 | 65535 | 0 | Day + Mo*32 + (Yr -1980)*256 |
Configuration | Data | 48 | 4 | H2 | Serial Number | 0 | ffff | 1 | hex |
Configuration | Data | 48 | 6 | U2 | Cycle Count | 0 | 65535 | 0 | Counts |
Configuration | Data | 48 | 8 | I2 | CC Threshold | 100 | 32767 | 900 | mAh |
Configuration | Data | 48 | 10 | U1 | Max Error Limit | 0 | 100 | 100 | % |
Configuration | Data | 48 | 11 | I2 | Design Capacity | 0 | 32767 | 1000 | mAh |
Configuration | Data | 48 | 13 | I2 | Design Energy | 0 | 32767 | 5400 | mWh |
Configuration | Data | 48 | 15 | I2 | SOH Load I | –32767 | 0 | –400 | mA |
Configuration | Data | 48 | 17 | U2 | Cell Charge Voltage T1-T2 | 0 | 4600 | 4200 | mV |
Configuration | Data | 48 | 19 | U2 | Cell Charge Voltage T2-T3 | 0 | 4600 | 4200 | mV |
Configuration | Data | 48 | 21 | U2 | Cell Charge Voltage T3-T4 | 0 | 4600 | 4100 | mV |
Configuration | Data | 48 | 23 | U1 | Charge Current T1-T2 | 0 | 100 | 10 | % |
Configuration | Data | 48 | 24 | U1 | Charge Current T2-T3 | 0 | 100 | 50 | % |
Configuration | Data | 48 | 25 | U1 | Charge Current T3-T4 | 0 | 100 | 30 | % |
Configuration | Data | 48 | 26 | I1 | JEITA T1 | –128 | 127 | –10 | °C |
Configuration | Data | 48 | 27 | I1 | JEITA T2 | –128 | 127 | 10 | °C |
Configuration | Data | 48 | 28 | I1 | JEITA T3 | –128 | 127 | 45 | °C |
Configuration | Data | 48 | 29 | I1 | JEITA T4 | –128 | 127 | 55 | °C |
Configuration | Data | 48 | 30 | U1 | Design Energy Scale | 0 | 255 | 1 | Num |
Configuration | Data | 48 | 31 | S12 | Device Name | x | x | BQ34Z100-G1 | — |
Configuration | Data | 48 | 43 | S12 | Manufacturer Name | x | x | Texas Inst. | — |
Configuration | Data | 48 | 55 | S5 | Device Chemistry | x | x | LION | — |
Configuration | Discharge | 49 | 0 | U2 | SOC1 Set Threshold | 0 | 65535 | 150 | mAh |
Configuration | Discharge | 49 | 2 | U2 | SOC1 Clear Threshold | 0 | 65535 | 175 | mAh |
Configuration | Discharge | 49 | 4 | U2 | SOCF Set Threshold | 0 | 65535 | 75 | mAh |
Configuration | Discharge | 49 | 6 | U2 | SOCF Clear Threshold | 0 | 65535 | 100 | mAh |
Configuration | Discharge | 49 | 8 | I2 | Cell BL Set Volt Threshold | 0 | 5000 | 0 | mV |
Configuration | Discharge | 49 | 10 | U1 | Cell BL Set Volt Time | 0 | 60 | 0 | s |
Configuration | Discharge | 49 | 11 | I2 | Cell BL Clear Volt Threshold | 0 | 5000 | 5 | mV |
Configuration | Discharge | 49 | 13 | I2 | Cell BH Set Volt Threshold | 0 | 5000 | 4300 | mV |
Configuration | Discharge | 49 | 15 | U1 | Cell BH Volt Time | 0 | 60 | 2 | s |
Configuration | Discharge | 49 | 16 | I2 | Cell BH Clear Volt Threshold | 0 | 5000 | 5 | mV |
Configuration | Discharge | 49 | 21 | U1 | Cycle Delta | 0 | 255 | 5 | 0.01% |
Configuration | Manufacturer Data | 56 | 0 | H2 | Pack Lot Code | 0 | ffff | 0 | hex |
Configuration | Manufacturer Data | 56 | 2 | H2 | PCB Lot Code | 0 | ffff | 0 | hex |
Configuration | Manufacturer Data | 56 | 4 | H2 | Firmware Version | 0 | ffff | 0 | hex |
Configuration | Manufacturer Data | 56 | 6 | H2 | Hardware Revision | 0 | ffff | 0 | hex |
Configuration | Manufacturer Data | 56 | 8 | H2 | Cell Revision | 0 | ffff | 0 | hex |
Configuration | Manufacturer Data | 56 | 10 | H2 | DF Config Version | 0 | ffff | 0 | hex |
Configuration | Lifetime Data | 59 | 0 | I2 | Lifetime Max Temp | 0 | 1400 | 300 | 0.1°C |
Configuration | Lifetime Data | 59 | 2 | I2 | Lifetime Min Temp | –600 | 1400 | 200 | 0.1°C |
Configuration | Lifetime Data | 59 | 4 | I2 | Lifetime Max Chg Current | –32767 | 32767 | 0 | mA |
Configuration | Lifetime Data | 59 | 6 | I2 | Lifetime Max Dsg Current | –32767 | 32767 | 0 | mA |
Configuration | Lifetime Data | 59 | 8 | U2 | Lifetime Max Pack Voltage | 0 | 65535 | 320 | 20 mV |
Configuration | Lifetime Data | 59 | 10 | U2 | Lifetime Min Pack Voltage | 0 | 65535 | 350 | 20 mV |
Configuration | Lifetime Temp Samples | 60 | 0 | U2 | LT Flash Cnt | 0 | 65535 | 0 | Counts |
Configuration | Registers | 64 | 0 | H2 | Pack Configuration | 0 | ffff | 161 | flags |
Configuration | Registers | 64 | 2 | H1 | Pack Configuration B | 0 | ff | ff | flags |
Configuration | Registers | 64 | 3 | H1 | Pack Configuration C | 0 | ff | 30 | flags |
Configuration | Registers | 64 | 4 | H1 | LED_Comm Configuration | 0 | ff | 0 | flags |
Configuration | Registers | 64 | 5 | H2 | Alert Configuration | 0 | ffff | 0 | flags |
Configuration | Registers | 64 | 7 | U1 | Number of series cell | 0 | 100 | 1 | Num |
Configuration | Lifetime Resolution | 66 | 0 | U1 | LT Temp Res | 0 | 255 | 10 | 0.1°C |
Configuration | Lifetime Resolution | 66 | 1 | U1 | LT Cur Res | 0 | 255 | 100 | mA |
Configuration | Lifetime Resolution | 66 | 2 | U1 | LT V Res | 0 | 255 | 1 | 20 mV |
Configuration | Lifetime Resolution | 66 | 3 | U2 | LT Update Time | 0 | 65535 | 60 | s |
Configuration | LED Display | 67 | 0 | U1 | LED Hold Time | 0 | 255 | 4 | Num |
Configuration | Power | 68 | 0 | I2 | Flash Update OK Cell Volt | 0 | 4200 | 2800 | mV |
Configuration | Power | 68 | 2 | I2 | Sleep Current | 0 | 100 | 10 | mA |
Configuration | Power | 68 | 11 | U1 | FS Wait | 0 | 255 | 0 | s |
System Data | Manufacturer Info | 58 | 0 | H1 | Block A 0 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 1 | H1 | Block A 1 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 2 | H1 | Block A 2 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 3 | H1 | Block A 3 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 4 | H1 | Block A 4 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 5 | H1 | Block A 5 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 6 | H1 | Block A 6 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 7 | H1 | Block A 7 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 8 | H1 | Block A 8 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 9 | H1 | Block A 9 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 10 | H1 | Block A 10 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 11 | H1 | Block A 11 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 12 | H1 | Block A 12 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 13 | H1 | Block A 13 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 14 | H1 | Block A 14 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 15 | H1 | Block A 15 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 16 | H1 | Block A 16 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 17 | H1 | Block A 17 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 18 | H1 | Block A 18 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 19 | H1 | Block A 19 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 20 | H1 | Block A 20 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 21 | H1 | Block A 21 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 22 | H1 | Block A 22 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 23 | H1 | Block A 23 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 24 | H1 | Block A 24 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 25 | H1 | Block A 25 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 26 | H1 | Block A 26 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 27 | H1 | Block A 27 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 28 | H1 | Block A 28 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 29 | H1 | Block A 29 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 30 | H1 | Block A 30 | 0 | ff | 0 | hex |
System Data | Manufacturer Info | 58 | 31 | H1 | Block A 31 | 0 | ff | 0 | hex |
Gas Gauging | IT Cfg | 80 | 0 | U1 | Load Select | 0 | 255 | 1 | Num |
Gas Gauging | IT Cfg | 80 | 1 | U1 | Load Mode | 0 | 255 | 0 | Num |
Gas Gauging | IT Cfg | 80 | 10 | I2 | Res Current | 0 | 1000 | 10 | mA |
Gas Gauging | IT Cfg | 80 | 14 | U1 | Max Res Factor | 0 | 255 | 50 | Num |
Gas Gauging | IT Cfg | 80 | 15 | U1 | Min Res Factor | 0 | 255 | 1 | Num |
Gas Gauging | IT Cfg | 80 | 17 | U2 | Ra Filter | 0 | 1000 | 500 | Num |
Gas Gauging | IT Cfg | 80 | 47 | U1 | Min PassedChg NiMH-LA 1st Qmax | 1 | 100 | 50 | % |
Gas Gauging | IT Cfg | 80 | 49 | U1 | Maximum Qmax Change | 0 | 255 | 100 | % |
Gas Gauging | IT Cfg | 80 | 53 | I2 | Cell Terminate Voltage | 1000 | 3700 | 3000 | mV |
Gas Gauging | IT Cfg | 80 | 55 | I2 | Cell Term V Delta | 0 | 4200 | 200 | mV |
Gas Gauging | IT Cfg | 80 | 58 | U2 | ResRelax Time | 0 | 65534 | 500 | s |
Gas Gauging | IT Cfg | 80 | 62 | I2 | User Rate-mA | –32767 | 32767 | 0 | mA |
Gas Gauging | IT Cfg | 80 | 64 | I2 | User Rate-Pwr | –32767 | 32767 | 0 | mW/cW |
Gas Gauging | IT Cfg | 80 | 66 | I2 | Reserve Cap-mAh | 0 | 9000 | 0 | mAh |
Gas Gauging | IT Cfg | 80 | 68 | I2 | Reserve Energy | 0 | 14000 | 0 | mWh/cWh |
Gas Gauging | IT Cfg | 80 | 72 | U1 | Max Scale Back Grid | 0 | 15 | 4 | Num |
Gas Gauging | IT Cfg | 80 | 73 | U2 | Cell Min DeltaV | 0 | 65535 | 0 | mV |
Gas Gauging | IT Cfg | 80 | 75 | U1 | Ra Max Delta | 0 | 255 | 15 | % |
Gas Gauging | IT Cfg | 80 | 76 | I2 | Design Resistance | 1 | 32767 | 42 | mΩ |
Gas Gauging | IT Cfg | 80 | 78 | U1 | Reference Grid | 0 | 14 | 4 | — |
Gas Gauging | IT Cfg | 80 | 79 | U1 | Qmax Max Delta % | 0 | 100 | 10 | mAh |
Gas Gauging | IT Cfg | 80 | 80 | U2 | Max Res Scale | 0 | 32767 | 32000 | Num |
Gas Gauging | IT Cfg | 80 | 82 | U2 | Min Res Scale | 0 | 32767 | 1 | Num |
Gas Gauging | IT Cfg | 80 | 84 | U1 | Fast Scale Start SOC | 0 | 100 | 10 | % |
Gas Gauging | IT Cfg | 80 | 89 | I2 | Charge Hys V Shift | 0 | 2000 | 40 | mV |
Gas Gauging | IT Cfg | 80 | 91 | I2 | Smooth Relax Time | 1 | 32767 | 1000 | s |
Gas Gauging | Current Thresholds | 81 | 0 | I2 | Dsg Current Threshold | 0 | 2000 | 60 | mA |
Gas Gauging | Current Thresholds | 81 | 2 | I2 | Chg Current Threshold | 0 | 2000 | 75 | mA |
Gas Gauging | Current Thresholds | 81 | 4 | I2 | Quit Current | 0 | 1000 | 40 | mA |
Gas Gauging | Current Thresholds | 81 | 6 | U2 | Dsg Relax Time | 0 | 8191 | 60 | s |
Gas Gauging | Current Thresholds | 81 | 8 | U1 | Chg Relax Time | 0 | 255 | 60 | s |
Gas Gauging | Current Thresholds | 81 | 9 | U2 | Cell Max IR Correct | 0 | 1000 | 400 | mV |
Gas Gauging | State | 82 | 0 | I2 | Qmax Cell 0 | 0 | 32767 | 1000 | mAh |
Gas Gauging | State | 82 | 2 | U2 | Cycle Count | 0 | 65535 | 0 | Num |
Gas Gauging | State | 82 | 4 | H1 | Update Status | 0 | 6 | 0 | Num |
Gas Gauging | State | 82 | 5 | I2 | Cell V at Chg Term | 0 | 5000 | 4200 | mV |
Gas Gauging | State | 82 | 7 | I2 | Avg I Last Run | –32768 | 32767 | –299 | mA |
Gas Gauging | State | 82 | 9 | I2 | Avg P Last Run | –32768 | 32767 | –1131 | mWh |
Gas Gauging | State | 82 | 11 | I2 | Cell Delta Voltage | –32768 | 32767 | 2 | mV |
Gas Gauging | State | 82 | 13 | I2 | T Rise | 0 | 32767 | 20 | Num |
Gas Gauging | State | 82 | 15 | I2 | T Time Constant | 0 | 32767 | 1000 | Num |
Ra Table | R_a0 | 88 | 0 | H2 | R_a0 Flag | 0 | ffff | ff55 | Hex |
Ra Table | R_a0 | 88 | 2 | I2 | R_a0 0 | 0 | 32767 | 105 | Num |
Ra Table | R_a0 | 88 | 4 | I2 | R_a0 1 | 0 | 32767 | 100 | Num |
Ra Table | R_a0 | 88 | 6 | I2 | R_a0 2 | 0 | 32767 | 113 | Num |
Ra Table | R_a0 | 88 | 8 | I2 | R_a0 3 | 0 | 32767 | 143 | Num |
Ra Table | R_a0 | 88 | 10 | I2 | R_a0 4 | 0 | 32767 | 98 | Num |
Ra Table | R_a0 | 88 | 12 | I2 | R_a0 5 | 0 | 32767 | 97 | Num |
Ra Table | R_a0 | 88 | 14 | I2 | R_a0 6 | 0 | 32767 | 108 | Num |
Ra Table | R_a0 | 88 | 16 | I2 | R_a0 7 | 0 | 32767 | 89 | Num |
Ra Table | R_a0 | 88 | 18 | I2 | R_a0 8 | 0 | 32767 | 86 | Num |
Ra Table | R_a0 | 88 | 20 | I2 | R_a0 9 | 0 | 32767 | 85 | Num |
Ra Table | R_a0 | 88 | 22 | I2 | R_a0 10 | 0 | 32767 | 87 | Num |
Ra Table | R_a0 | 88 | 24 | I2 | R_a0 11 | 0 | 32767 | 90 | Num |
Ra Table | R_a0 | 88 | 26 | I2 | R_a0 12 | 0 | 32767 | 110 | Num |
Ra Table | R_a0 | 88 | 28 | I2 | R_a0 13 | 0 | 32767 | 647 | Num |
Ra Table | R_a0 | 88 | 30 | I2 | R_a0 14 | 0 | 32767 | 1500 | Num |
Ra Table | R_a0x | 89 | 0 | H2 | R_a0x Flag | 0 | ffff | ffff | Hex |
Ra Table | R_a0x | 89 | 2 | I2 | R_a0x 0 | 0 | 32767 | 105 | Num |
Ra Table | R_a0x | 89 | 4 | I2 | R_a0x 1 | 0 | 32767 | 100 | Num |
Ra Table | R_a0x | 89 | 6 | I2 | R_a0x 2 | 0 | 32767 | 113 | Num |
Ra Table | R_a0x | 89 | 8 | I2 | R_a0x 3 | 0 | 32767 | 143 | Num |
Ra Table | R_a0x | 89 | 10 | I2 | R_a0x 4 | 0 | 32767 | 98 | Num |
Ra Table | R_a0x | 89 | 12 | I2 | R_a0x 5 | 0 | 32767 | 97 | Num |
Ra Table | R_a0x | 89 | 14 | I2 | R_a0x 6 | 0 | 32767 | 108 | Num |
Ra Table | R_a0x | 89 | 16 | I2 | R_a0x 7 | 0 | 32767 | 89 | Num |
Ra Table | R_a0x | 89 | 18 | I2 | R_a0x 8 | 0 | 32767 | 86 | Num |
Ra Table | R_a0x | 89 | 20 | I2 | R_a0x 9 | 0 | 32767 | 85 | Num |
Ra Table | R_a0x | 89 | 22 | I2 | R_a0x 10 | 0 | 32767 | 87 | Num |
Ra Table | R_a0x | 89 | 24 | I2 | R_a0x 11 | 0 | 32767 | 90 | Num |
Ra Table | R_a0x | 89 | 26 | I2 | R_a0x 12 | 0 | 32767 | 110 | Num |
Ra Table | R_a0x | 89 | 28 | I2 | R_a0x 13 | 0 | 32767 | 647 | Num |
Ra Table | R_a0x | 89 | 30 | I2 | R_a0x 14 | 0 | 32767 | 1500 | Num |
Calibration | Data | 104 | 0 | F4 | CC Gain | 1.00E-01 | 4.00E+01 | 0.4768 | mΩ |
Calibration | Data | 104 | 4 | F4 | CC Delta | 2.98E+04 | 1.19E+06 | 567744.56 | mΩ |
Calibration | Data | 104 | 8 | I2 | CC Offset | –32768 | 32767 | –1200 | Num |
Calibration | Data | 104 | 10 | I1 | Board Offset | –128 | 127 | 0 | Num |
Calibration | Data | 104 | 11 | I1 | Int Temp Offset | –128 | 127 | 0 | 0.1°C |
Calibration | Data | 104 | 12 | I1 | Ext Temp Offset | –128 | 127 | 0 | 0.1°C |
Calibration | Data | 104 | 14 | U2 | Voltage Divider | 0 | 65535 | 5000 | mV |
Calibration | Current | 107 | 1 | U1 | Deadband | 0 | 255 | 5 | mA |
Security | Codes | 112 | 0 | H4 | Sealed to Unsealed | 0 | ffffffff | 36720414 | hex |
Security | Codes | 112 | 4 | H4 | Unsealed to Full | 0 | ffffffff | ffffffff | hex |
Security | Codes | 112 | 8 | H4 | Authen Key3 | 0 | ffffffff | 1234567 | hex |
Security | Codes | 112 | 12 | H4 | Authen Key2 | 0 | ffffffff | 89abcdef | hex |
Security | Codes | 112 | 16 | H4 | Authen Key1 | 0 | ffffffff | fedcba98 | hex |
Security | Codes | 112 | 20 | H4 | Authen Key0 | 0 | ffffffff | 76543210 | hex |